FHA FHB FHC Meter Units (For Resistance System )

Short Description:

Meter units FHA FHB FHC are oil proportioning devices for single line resistance cyclic systems
Each outlet of a Lubricating system is controlled by a meter unit. The lubricator in the system dispenses oil to the distribution network and meter unnits deliver this oil in varyting amounts to the friction points .
1.Working Pressure:0.2-2Mpa (2-20kgf/cm2)
2.Oil Viscosity (40c ): 20-500cst
3.Flow Rate :The flow will be multiplied via serial number sequenc.
4.FHA connected to PV/PVS distributor. FHB connector to equipment lubrication point .


Product Detail

Product Tags

Proportional restrictor rod  /Product drawings and dimensions:

Draft Model Number Body Mark Code Type L S SPE FLOW RATE(prorate distribution) A Inner thead B Outer Thread OIL VISCOSITY
 12222 FHA-00 AJB/DPC 10505-1-00 Meter Unit 28 10 OO 2.5 M8X1 M8X1 20-500cst
FHA-0 DPC 10505-1-0 0 5
FHA-1 10505-1-1 1 10
FHA-2 10505-1-2 2 20
FHA-3 10505-1-3 3 40
FHA-4 10505-1-4 4 80
FHA-5 10505-1-5 5 160

 

Draft Model Number Body Mark Code Type L S SPE FLOW RATE(prorate distribution) A Inner thead B Outer Thread OIL VISCOSITY
 q1q2 FHB-00 AJB/DPC 10505-2-00 Meter Unit 24 10 OO 2.5 M8X1 R1/8 20-500cst
FHB-0 DPC 10505-2-0 0 5
FHB-1 10505-2-1 1 10
FHB-2 10505-2-2 2 20
FHB-3 10505-2-3 3 40
FHB-4 10505-2-4 4 80
FHB-5 10505-2-5 5 160

 

Draft Model Number Body Mark Code Type L S SPE FLOW RATE(prorate distribution) A Inner thead B Outer Thread OIL VISCOSITY
w2w3 FHC-0 SS 10505-3-0 Meter Unit 28 10 0 5 M8X1 M8X1 20-500cst
FHC-1 10505-3-1 1 10
FHC-2 10505-3-2 2 20
FHC-3 10505-3-3 3 40
FHC-4 10505-3-4 4 80
FHC-5 10505-3-5 5 160

 

Performance and characteristics

1.FHA/FHB/FHC type resistance measuring parts are also called proportional joints.
2. Tubular structure with restrictor rod and check valve.
3. Opening pressure: 0.2MPa
4. Control the flow through the throttling principle and distribute the flow proportionately according to the flow capacity (flow number). The far,near, high, low, horizontal or vertical installations in the relubrication system of the same type of metering component are all basically the samein actual use. Long service life, the proportion of joints check valve rubber seal external pressure test copper sleeve (except the sealing surface) to prevent rubber seals from swelling and aging.
5. Sensitive operation and smooth oil discharge: The proportional joint check valve adopts conical spring to ensure that the metering part is sensitive and oil-free and prevents the excluded oil agent from flowing backwards.
6. Flow ratio: The flow of the same model will change with the change of the ambient temperature and the viscosity of the oil during the actual use.

 

 

 


  • Previous:
  • Next:

  • Write your message here and send it to us